Home > Buy Now > Heart Rate Monitor > Fetal/Maternal Monitor
 


Guoteng
 
icon Multi-parameter Patient Monitor
icon ECG Machine 803

line

icon Company Profile
icon Selling Leads

line

 
Contact us
Guoteng
[China]
Address:
Three-Dimension Science&Technology Builing,No.184 Bailian Road,Jida Zhuhai Guangdong 519015 China
Phone:
86-756-3321671
Contact name:
anna , manager
Inquire now










Guoteng



 
Multi-parameter Patient Monitor

Fetal/Maternal Monitor

Inquire now

Fetal/Maternal Monitor

Click to enlarge image

 Model Number GT9002

Specifications of GT9002 Fetal/Maternal Monitor
(Standards of IEC60601 and GB9706)

Operating:
Temperature 5~40 degrees Celsius Humidity = 80%

Storage: Temperature -20~55 degrees Celsius Humidity = 93%

Battery: Built-in rechargeable battery,
maximum utility time = 2 hours

Trend Observation: 1~72 hours trend graphics

Network: Compatible with central monitoring system

Recorder: Built-in, thermal

Recording Modes: Manual, alarm and timing

Ultrasonic Probe:
(Fetal Heart Rate)
Type B Proof, Directional
Using Pulse Doppler system
Working Frequency: 2.5MHz
Transmitting Power Density:
1.2m W/cm2
Using the multi-wafer probe
Sampling Rate: ±5ms
Calculating Precision of Fetal Heart Rate: ±0.25bpm
Accuracy of Fetal Heart Rate: ±1bpm (100-180bpm)

Marker
(Fetal Movement)

Manual Push Button Mode
(Operated by the monitored person).
When pressed, a red strip will be displayed above
the Fetal Heart Rate graph.

Uterine Contraction Pressure
Type B Proof
Uterine Contraction Pressure probe
Manual Zero Adjustment

Design Pressure Sensitivity: 0-100%ECG

Displaying graphics of 7 leads on the same screen

Overload protection: Defibrillation.
Anti the interference of high-frequency electrotome

Lead: 5 leads (RA, LA, V, RL, LL)

Lead Selection: I; II; III; avR; avL; avF; V;

Waveform: 4 channels

Gain Selection: �0. 5; �1; �2; �4

Electrical Leakage : < 30uA

Baseline Recovery Time: <3 sec following
defibrillation

Protection: separates and withstands
4000V AC/50Hz defibrillation,
resistant to interference of electrotome
and myoelectricity

Scan Speed: 12.5mm/25mm/50mm/sec

Lead Drop: auto detection
Modes: DIA: 0.05~100Hz
MON: 0.5~35Hz
OPE: 1~25HzRESP
Model: RA-LL impedance
Measurement /alarm range:1�99 rpm
Resolution: 1rpm.
Accuracy: ±2rpm.
TEMP
Resolution: 0.1 degrees Celsius
Accuracy: ±0.2 degrees Celsius
Channel: 2 channels
Average measurement Time: < 10sec
Alarm: Sound, light

NIBP
Unique Direct, Reverse and Quick modes
Method: automatic oscillometric
Working Mode: Auto/Manual
Interval of Auto Mode: 1-60 min

PR Range: 0-300 bpm
Measurement Unit: mmHg/Kpa Selectable
Measurement Ranges: Systolic BP,
Diastolic BP and Mean BP
Applicability: Adult/Pediatric/Neonatal
Overload protection: Dual security protectionSpO2

SpO2 probe of high intensity and durability
Excellent measurement of low perfusion.
Anti interference of movement
Measurement Range: 0-100%
Alarm range: 0-100%
Resolution: ±1%
Accuracy: ±2% (80-100%)
±3% (60-79%)

PR range: 0~300bpm

HR
A. Measurement Range: 0-300bpm
B. Accuracy: ±1bpm or ±2%
C. Resolution: 1bpm
D. ECG Calibration: 1mV (Peak Value)
ST Segment offset (Diagnose Mode)
A. Measurement Range: -0.8mV~2.0mV
B. Accuracy: ±0.02mV or ±5%

Standard Equipment: Uterine Contraction Pressure + Fetal Movement + ECG + NIBP + SpO2 + RESP + PR + TEMP + Built-in Battery

Optional Equipment: Built-in thermal printer + dual channel Temp probe.






Inquire now


   
 
 

Related products from premium suppliers on EC21